In this guide we’re running through the deployment of VCF 9.1, the latest GA drop from Nov 2026. I’ve covered this pretty heavily in VCF 9.0 and even the old v5 days, but this is a full end‑to‑end deployment of 9.1 to see exactly what’s changed.
VCF 9.1 — What’s New
VCF 9.1 adds VCF Management Services — a common runtime unifying lifecycle and operational capabilities including the License Server, Software Depot, and Salt RaaS in a consolidated cluster.
ESX — Memory Tiering — Software RAID1 mirroring for Memory Tiering is introduced — if one NVMe device fails, the secondary device continues memory tiering, preventing failure regardless of device wear-out
Native S3 Object Storage — managed with the same workflows as block and file storage
APIs —vCenter now supports OAuth 2.0 API tokens.
DRS & vMotion – Intel QAT offload for encrypted vSphere vMotion reduces source CPU utilization by nearly 67% and destination by nearly 22%, with significantly lower variance in total migration time.
VPC Transit Gateway, Traceflow, and Live Traffic Analysis are now configurable from the vSphere Client,
VAAI-NAS Unmap support added for NFS v4.1, enabling space reclamation for VMs on thin-provisioned NFS v4.1 datastores
VCF 9.1 — Lab Deployment
If you’re planning to try this in the lab, the whole stack will happily chew through around 600 GB of RAM. This entire setup is running on a single physical ESXi host, and for this build I’m using a HP ProLiant DL380 Gen10 with 756 GB RAM. For this deployment, I’ve ensured my base ESX host is on 8.0 U3 and have used the concept of NVMe tiering to double the ram capacity

NVMe Tiering

The deployment can be done on two nodes using NFS /FC and a miniinum of three nodes if vSAN is chosen. In this guide we will go for NFS on the management cluster and vSAN on the workload domain.
Management Domain
| Component | Specification |
| vCPU | 34 with HW virtualization turned on |
| Memory | 200 GB |
| Disk | NVMe Controller 1×40 GB NVMe for ESXi installation 1×450 GB NVMe |
| Network | 4×10 GBPS connected to trunk port group uplink1 and uplink 2 for vSAN, mgmt and vMotion uplink3 and uplink 4 for NSX |
Management Domain fqdn & Ip Pools
Management Domain
- Management – VLAN 1611
- vMotion – VLAN 1612
- vSAN & NFS– VLAN 1613
- NFS – VLAN 999
- NSX Host TEP – VLAN 1613
- NSX Edge TEP – VLAN 2713
- Edge Uplink 1 – VLAN 2712
- Edge Uplink 2 – VLAN 2713
Prepare all DNS enteries required

VCF 9.1 Bill of Materials
VCF 9.1 Deployment Mandatory Pre Install Checklist
- A minimum of 4 physical servers for vSAN with preinstalled VMware ESX ESX 9.1 hypervisor is required else 2 hosts if NFS/FC route is chosen
- Hardware virtualization must be enabled on the base host
- Generate host certificates and host names correctly
- Static IP Address assigned to the Management interface (vmk0)
- ESXi must have ‘VM network’ and ‘Management network’ VLAN id of mgmt configured was the default in VCF 9.X but this is no longer required.
- NTP server address should be in place on all ESXi and set to sync to Chrony
- Ensure that your software depot is configured
- SSH & NTP and activity directory service to be enabled to start with the host
- vSAN ESA Disk & HCL workaround for VCF 9.0 followed by a host reboot
- No real requirement for NFS datastore pre-mount on VCF 9.1
- Ensure the cloud builder/vcf installer appliance NTP sync works correctly.
- A DHCP server to configure the IP address for the VTEP on each ESXi hosts
- An NVMe controller replaces the SCSI controller and this is required for vSAN ESA
- MTU must be 9216 (recommended) or at minimum 1600 for NSX overlay.
- No uppper case letters should used anywhere in the deployment of endpoints such as for hosts,vCenters etc
- Do not use capital letters in the FQDN.
- All passwords must be:≥ 15 characters, only allowed special characters:!@#$%^&*
- Forward and reverse records for every endpoint.
Installing a new NFS Server
You could use any NAS utility to grant us NFS shares but here I’m just natively using a new VM just for NFS and that grants out a 4 TB NFS volume that will be consumed by VCF
- https://vmanalyst.com/nfs-server-for-the-vcf-management-domain/
- https://vmanalyst.com/vcf-9-1-1-principal-nfs-deployment-gateway-bug/
NFS server VM (sfo-nfs01)
| Disk | Size | Why |
|---|---|---|
| OS | 40 GB | Ubuntu Server needs about 10 GB. The rest covers logs and updates. |
Data (/export/vcf-mgmt) | 4 TB; 2 TB minimum | It holds the whole management domain, see below |
Ensure the NTP is synced to chrony.
Host Configuration
The hosts are setup as shown

- Uplink 1 – Mgmt + Storage + vMotion
- Uplink 2– Mgmt + Storage + vMotion
- Uplink 3– NSX
- Uplink 4 – NSX
Disable Synchronize time with host if deploying as a nested vm

ESX Install and Configuration
For most bits, the esx install is the same usual stuff but i will add the main bits into this post
- Convert the ESX image into a bootable one using Rufus and attach it to USB drive
- Install the ESX Image onto the root drive
- Choose the keyboard layout
- Press enter on VLAN and give the ESX management VLAN
- Ensure static address is set
- Set Certificates, Hostname and NTP via Chrony
- Ensure password is 15 characters
Select enter to continue

Accept the EULA

Insall the OS into the 40 GB drive

Select keyboard layout

Provide a simple password here, this can be changed later before vcf installer kicks in

Ignore CPU warning on the lab


Wait for few mins to complete the install

Press F2 to login to DCUI and change vlan to 1611

Set a static IP and add your management IP details in

Disable IPV6 if required

Add DNS server and the hostname for this server

Provide domain under DNS Suffixes and press Enter

Restart the system

Login to UI and change root password to 15 character

Login to UI and enable ssh

Set Certificates, 15 charcater Password,Hostname and NTP
Set the hostname, generate the certificates, and make sure NTP is actually working .The ESXi certificate must use the FQDN, and it must be lowercase. No exceptions. Hostname should match the FQDN exactly — again, all lowercase.
# Specify at least one of: --host, --domain, --fqdn
esxcli system hostname set --host=sa-esx02
esxcli system hostname set --fqdn=sa-esx02.ash.local
# Generate Certificates
/sbin/generate-certificates
ls -l /etc/vmware/ssl/
# Deploment for nested lab
esxcli software acceptance set --level CommunitySupported
Host acceptance level changed to 'CommunitySupported'.
esxcli software vib install -v /nested-vsan-esa-mock-hw.vib --no-sig-check
esxcli software vib install -v /vmfs/volumes/2999b9f4-c0675609/vib20/nested-vsan-esa-mock-hw/williamlam.com_bootbank_nested-vsan-esa-mock-hw_1.0.0-1.0.vib
esxcli storage nfs remove -v NFS2
Set NTP on ESX Servers
# Conifgure ntp to chrony
esxcli system ntp set --server 172.16.11.251 --enabled true
/etc/init.d/ntpd start
chkconfig ntpd on
esxcli system ntp get
ntpq -p
#Change root password
esxcli system account set -i root -p 'NewPassword' -c 'NewPassword'
restart all services
# /etc/init.d/hostd restart && /etc/init.d/vpxa restartChange root password to 15 characters
#Change root password
esxcli system account set -i root -p 'NewPassword' -c 'NewPassword'Restart all services
restart all services
# /etc/init.d/hostd restart && /etc/init.d/vpxa restart
If you’re running this on hardware that VCF/ESXi 9.1 doesn’t officially like, you’ll need to add the CPU override flags into boot.cfg so the installer doesn’t bail out.
Add the following options to the boot.cfg kernel line:
allowLegacyCPU=true
ignoreUnsupportedCPU=true

ESX must have ‘VM network’ and ‘Management network’ VLAN id of mgmt configured as shown on the vmkernel0

Reboot the host, leave the ssh running

Verify vmnic alignment
On some servers, especially older Gen9/Gen10 boxes or anything running quirky PCI layouts, the vmnic numbering doesn’t always line up with the actual PCI devices. VCF won’t care until NSX comes into play — then it becomes a problem.
Use esxcli network nic list to confirm vmnic → MAC → PCI mapping.
for i in 0 1 2 3 4 5 6 7; do
echo "=== vmnic$i ==="
localcli --plugin-dir /usr/lib/vmware/esxcli/int/ deviceInternal alias list | grep "vmnic$i$"
done
The pci and logical numbers should clearly match.

If its not a match, align the PCI Interfaces correctly
localcli --plugin-dir /usr/lib/vmware/esxcli/int/ deviceInternal alias list > /tmp/alias_backup_$(date +%F).txt
Fix commands for physical devices
localcli --plugin-dir /usr/lib/vmware/esxcli/int/ deviceInternal alias store --alias vmnic0 --bus-address s00000002:03.00 --bus-type pci
Fix commands for logical devices
localcli --plugin-dir /usr/lib/vmware/esxcli/int/ deviceInternal alias store --alias vmnic0 --bus-address pci#s00000002:03.00#0 --bus-type logical
Certificate Requirements
Once the above tasks are done, get all certificates from the ESX server
# get cert out
[root@sfo-m01-esx01:~] openssl x509 -in /etc/vmware/ssl/rui.crt -fingerprint -sha256 -noout | cut -d'=' -f2
EE:FF:23:97:14:51:5B:9F:1A:AE:8B:91:2A:E8:3A:06:1F:A2:77:9B:9A:27:75:BF:23:18:56:AA:CB:1A:11:F6
[root@sfo-m01-esx02:~] openssl x509 -in /etc/vmware/ssl/rui.crt -fingerprint -sha256 -noout | cut -d'=' -f2
DF:C6:E7:CD:3D:BB:E1:D8:25:A4:5D:FB:A4:C1:54:DD:79:62:D9:89:54:C0:C3:34:CE:BD:52:DF:87:DC:12:B7
root@sfo-m01-esx03:~] openssl x509 -in /etc/vmware/ssl/rui.crt -fingerprint -sha256 -noout | cut -d'=' -f2
11:73:B1:BE:D8:36:9D:2F:53:3D:33:52:56:A7:46:C4:03:26:0F:2D:1F:83:A0:C7:17:60:B5:A4:6C:25:2F:13
[root@sfo-m01-esx03:~]Network Requirements
For this deployment we’re sticking with the usual VCF networking expectations. Jumbo Frames (MTU 9000) are recommended across all VLANs, but at an absolute minimum you need 1600 MTU for NSX‑T overlays to function. Anything lower and you’ll hit packet drops the moment Geneve traffic shows up.
These are the port groups we’ll be creating for the VCF bring‑up, and because this is a nested vCloud Foundation setup, you need all the virtual networks in place before Cloud Builder even gets a look in.
A nested vCloud Foundation deployment requires multiple virtual networks to be in place before we can start the deployment. As part of this deployment, we’ve bgp configured on the vyOS tor routers.
| Network Type | VLAN | PortGroup |
| Management Network | 1611 | pg-mgmt-1611 |
| vMotion Network | 1612 | pg-vMotion-1612 |
| vSAN Network | 1613 | sfo-m01-cl01-vds01-pg-nfs |
| NSX-T-Host Overlay | 1634 | pg-host-overlay-1634 |
| NSX-T-edge-uplink-1 | 2711 | pg-nsx-t-edge-overlay |
| NSX-T-edge-overlay | 2713 | pg-nsx-t-edge-overlay |
| SDDC-vcF-TRUNK | 4095 | Trunk Port |
VCF Installer
Download and deploy the OVA from the VMware portal.

I am going to install on this on my onprem node than deploying it inside the first node, however should you want to install it within one of your new vcf hosts that can be done by editing one of the existing portgroups VM Network and changing the portgroup to 1611

Change VLAN to 1611

Choose Deploy OVF Template & pick SDDC Manager OVA

Give the VM a name

Choose the deployment target

Click Next

Accept the EULA

Select the datastore and pick Thin Provision

Deploy it to our management VLAN 1611

Provide a 15 character password ( accepted characters being !@#$%^&*)

Provide the hostname and NTP

For the networking section provide the host IP Details

Provide DNS domain and search domain path and DNS servers comma separated

Review and Finish

Make sure NTP sync is configured properly on the VCF installer. This is one of the most common failure points.
Cloud Builder is extremely sensitive to time drift — if the clock between the installer and the ESXi hosts drifts by more than ~30 seconds, the deployment can fail with completely unhelpful errors.
Login to VCF Installer as vcf@172.16.11.19 and then su root

Configure NTP On VCF Installer correctly

William Lam has documented quite a lot of hot fixes that can be applied . A few of them I used are here.
# Increase VCF Management Services Deployment Timeout
echo "vsp.bootstrap.task.timeout.minutes = 240" >> /etc/vmware/vcf/domainmanager/application.properties
echo "vsp.bootstrap.command.timeout.minutes = 200" >> /etc/vmware/vcf/domainmanager/application.properties
# Increase General Retry
echo "orchestrator.task.retry.max = 5" >> /etc/vmware/vcf/domainmanager/application.properties
# Increase NSX Manager Timeout
echo "nsxt.manager.wait.minutes = 180" >> /etc/vmware/vcf/domainmanager/application.properties
# Increase NSX Edge Timeout
echo "edge.node.vm.creation.max.wait.minutes = 90" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable 10GbE pNIC Check
echo "enable.speed.of.physical.nics.validation = false" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable vSAN ESA HCL Check
echo "vsan.esa.sddc.managed.disk.claim = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable vMotion Connectivity Check
echo "validation.disable.vmotion.connectivity.check = true" >> /etc/vmware/vcf/domainmanager/application.properties
echo "validation.disable.vmotion.l3.gateway.connectivity.check = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable vSAN Connectivity Check
echo "validation.disable.vsan.connectivity.check = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable TEP MTU Check
echo "validation.disable.network.connectivity.check = true" >> /etc/vmware/vcf/domainmanager/application.properties
echo "nsxt.mtu.validation.skip = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Disable NFS Connectivity Check
echo "validation.disable.nfs.configuration.connectivity.check = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Single Node AVI Load Balancer
echo "feature.vcf.vgl-41078.alb.single.node.cluster = true" >> /etc/vmware/vcf/domainmanager/application.properties
# Restart domainmanager
systemctl restart domainmanagerAlso add to operationsmanager (needed for vSAN ESA HCL and 10GbE checks):
echo "enable.speed.of.physical.nics.validation = false" >> /etc/vmware/vcf/operationsmanager/application-prod.properties
echo "vsan.esa.sddc.managed.disk.claim = true" >> /etc/vmware/vcf/operationsmanager/application-prod.properties
systemctl restart operationsmanagerAnd feature.properties (for single host and vSAN ESA):
echo "feature.vcf.vgl-29121.single.host.domain = true" >> /home/vcf/feature.properties
echo "feature.vcf.vgl-43370.vsan.esa.sddc.managed.disk.claim = true" >> /home/vcf/feature.properties
echo 'y' | /opt/vmware/vcf/operationsmanager/scripts/cli/sddcmanager_restart_services.shNFS Storage Requirements
There is no requirement in 9.1 to premount NFS Datastores on first host, follow these posts to ensure NFS Storage is set correctly
https://vmanalyst.com/nfs-server-for-the-vcf-management-domain/
https://vmanalyst.com/vcf-9-1-1-principal-nfs-deployment-gateway-bug/
VCF Installer – Initial Login
Before you kick off the installer, ensure NTP Is in sync across all

Log in to the VCF Installer VM using the web UI and move past the initial welcome screen. URL for this setup:
https://sfo-vcfinst01.ash.local
Once you’re in, the first thing the installer will complain about is software binaries. VCF needs either:
- a configured download token in the depot settings, or
- an offline depot already uploaded.
If you haven’t generated a token yet, follow the VMware instructions and create one — you’ll need it for the automated bundle downloads.
From the main screen, click: Depot Settings and Binary Management. This is where you add your token, confirm connectivity, and verify that Cloud Builder can actually pull the required bundles before you move on.

From the Depot Settings and Binary Management page, click the Connect to the Online Depot widget, then hit Configure.

Copy the service ID from the VCF Installer screen, then head over to: vcf.broadcom.com
Paste the service ID into the registration field and click Register. This links your Cloud Builder instance to the online depot so it can actually pull the bundles.

Click Software depot registration and click new registration


Take the activation code you generated on the Broadcom portal and paste it into the Activation Code field in the VCF Installer. Once it’s in, click Authenticate.

If the code is valid, the installer will confirm the connection and you’ll see the depot status change to authenticated.

Our service-id is registered

Once the activation code is authenticated and the depot connection shows as valid, click Download All.

Navigate back to the home screen to launch the deployment wizard. Depending on your use case, you can choose to deploy either VMware Cloud Foundation or vSphere Foundation.
Configs can be imported

Else its deployed via UI workflow

Click Next

Since I am performing a greenfield deployment, I selected the first option to deploy a new VCF fleet. If you already have an existing VCF fleet and want to scale your environment, choose the second option to deploy an additional VCF instance into the existing fleet.

If you are performing a brownfield deployment and need to import VCF Operations or VMware vCenter, select the corresponding option.

Simple works really well for a lab but in production so the rule of thumb: anything you can’t change later, decide up front. Anything you can grow, start small.
Production:
- Choose HA. Three NSX Managers, HA for VCF Operations and the HA Management Services. It costs about 30 vCPU and 84 GB of RAM more than Small non-HA, but it’s the model that’s hard to change afterwards, and it’s what support and audits expect.
- Leave NSX at its default size. Resize to Large only when you approach its limits, such as the sixth NSX-prepared cluster on Medium.
- Size the management cluster for N+1: the total from the chart plus one host’s worth of spare capacity, so you can patch a host or lose one without running out.
- Deploy VCF Automation only if it’s needed on day one. Adding it later is fine, but you can never size it down.
Lab :
- Choose Simple / Small non-HA: 70 vCPU, 231 GB of RAM, about 6.4 TB provisioned (thin).
- Skip VCF Automation at first. Add it after the core works, if RAM allows.

Typically if HA chosen, it will consume around 15 TB for a large
| Profile | vCPU | RAM (GB) | Disk (GB, provisioned) |
|---|---|---|---|
| Small non-HA | 70 | 231 | 6,422 |
| Small HA | 100 | 315 | 7,597 |
| Medium | 178 | 636 | 10,519 |
| Large | 292 | 929 | 14,531 |
For Network options, choose Cutomize

Under the VPC Gateway Connectivity, pick the transit gateway as Centralized. If you are wondering why its Centralized, its due to the fact that it deploy edge nodes so our VM’s in our overlay can talk to outside world. If distrbuted is chosen, there are no edge nodes deployed

Select principle storage type: vSAN, VMFS on Fibre Channel, or NFS v3.

Select NFS v3 Storage in our lab .

Review and click proceed


You can either prefill this section using an exported JSON from a previous deployment, or just enter everything one field at a time. For this lab we’re entering the values manually.
These are the parameters you need to provide:
- VCF version — Select the version matching the bundles you downloaded.
- VCF instance name — Lowercase only, no spaces, no uppercase.
- Management domain name — This becomes the SDDC Manager domain.
- DNS domain name — Must match your environment’s FQDN structure.
- DNS servers — Forward and reverse lookup must work.
- NTP servers — Must be reachable and in sync with Cloud Builder and ESXi.

Enter the root password and FQDN for each ESXi host in the management domain and confirm all fingerprints


Here we need 12 IPs for current scope or 30 IPs to allow for more components like VCF automation etc and auto-scaling for these VCF Management Services and automation so just reserve 30 IP’s

Choose the following
VCF Automation IP Range 172.16.11.200-172.16.11.225
vMotion Network (VLAN 1612): 172.16.12.0/24
vSAN/NFS Network (VLAN 1613): 172.16.13.0/24
Host Tep Pool Network (VLAN 1634): 172.16.34.0/24
Enter the FDQN values for these here
- VCF Operations Collector Appliance FQDN
- VCF Operations License Server FQDN
- VCF Fleet Services
- VCF Insatance services FQDN
- VCF Cloud proxy FQDN
- Identity Broker FQDN
- VCF AutomationFQDN
- VCF Automation Services Runtime


Enter the vCenter and cluster details

Enter the NFS datastore name, this needs to patch the pre mount name we did when building the host, as well as the path and NFS server, we also need to enable Bind To VMK to ensure traffic flows down this port, as we configured this when mounting the datastore for the pre mount, we must ensure this matches

Under the distributed switch, we have 4 NIC’s on our ESX host .Uplinks 1–2 carrying management, storage and vMotion, with uplinks 3–4 for NSX, is the NSX Traffic Separation row. If we had six NIC’s on our host, we can go for Storage Traffic And NSX Traffic Separation

Leave everything as default

Enter the FQDN for the NSX VIP and NSX Mgr

Deploy a new SDDC manager

Click review

Run all validations

After successful validation click deploy to start the deployment. The deployment takes few hours to complete.

Download the JSON specification and the passwords.

Logout of UI and monitor via shell. This will take around 8 hours to complete

Here are the list of VM’s deployed

View from Distributed switch

Login via VCFOps to validate everything.

vCF Build Logs
The location of the log file is /var/log/vmware/vcf/domainmanager in the VCF Installer VM. This file will give you a live update of the deployment and any errors if any
Bringup logs ( VCF Installer):
/var/log/vmware/vcf/bringup/vcf-bringup-debug.logSDDC Manager (VCF 9.x):
/var/log/vmware/vcf/domainmanager/domainmanager.log
VCF Fleet Management:
/var/log/vrlcm/vmware_vrlcm.logCollect all logs via SOS bundle:
# All logs
/opt/vmware/sddc-support/sos --collect-all-logs --zip
# VCF Installer logs only
/opt/vmware/sddc-support/sos --vcf-installer-logs --zip
# SDDC Manager logs only
/opt/vmware/sddc-support/sos --sddc-manager-logs --zipSome helpful commands for host perf monitoring
grep -iE "performance has deteriorated|latency" /var/log/vmkernel.log | tail -10
grep -E "2026-11-28T18:1[0-5]" /var/log/vmkernel.log | grep -viE "CpuSched|J6Async" | tail -40
grep -E "2026-11-28T18:1[0-5]" /var/log/hostd.log | grep -iE "esx03|error|warn" | tail -20
grep -iE "panic|nmi|lost|heartbeat|nvme.*(reset|timeout|abort)" /var/log/vmkernel.log /var/log/vobd.log 2>/dev/null | tail -20the next one we will set up our NSX